We understand that there are certain queries that often asked and so we decided to bring forth to You, our clients and customers a common platform where all frequently asked questions and queries are answered to the best of our abilities.
1. What is the vibration mechanism ?
The vibration is achieved by using a electromagnetic vibrator table. It has been observed that dry filling of fine lead dust in tubular bags is best achieved using such a mechanism instead of unbalanced motors or cam type vibrators or jolters.
2. Can the vibration be adjusted ?
Yes - it can be adjusted using the controller provided in the control panel along with the Positive Tubular Plate Filling Machine. Additional settings can be done by adjusting the vibrator base bolts. Please refer to O & M manual for a detailed sketch and instructions pertaining to this adjustment.
3. Can the Positive Tubular Plate Filling Machine be used to fill 6 mm dia tubular bags ?
Yes - the machine can fill plates having.
5.7 mm, 6.0 mm, 8.0 mm, 8.4 mm dia. tubular bags with correspondingly suitable spine thicknesses.
25 spines, 23 spines, 19 spines or 15 spines tubular plates – up to a max. width of approx. 190 mm.
95 mm, 105 mm … up to 540 mm ht. plates.
4. What is the duration required for filling?
The actual time of vibration filling is 1½ mins. However the loading of grids fitted with tubular bags into the cassette, subsequent vibration and unloading of filled plates from the cassette usually needs 4 to 6 mins. per cycle.